    AUTOMATIC DIESEL GENERATORS

    GRUPELquality, reliability and efficiency

    AUTOMATIC DIESEL GENERATORS 8-81 kWA

    SMARTRange

    8-81kVA – the range of Smart Range diesel generators consists of products suitable for reserved power supply of residential buildings and small to medium-sized businesses. Generators are available with Grupel own brand motors .

    AUTOMATIC DIESEL GENERATORS 87-700kVA

    INDUSTRIALRange

    The Industrial Range 87-700kVA industrial diesel generators have been specially developed for the industrial sector and are designed to operate as a primary or emergency power source. These generators are designed for a diverse range of applications.

    AUTOMATIC DIESEL GENERATORS 700-1000kVA

    HEAVYRange

    700-1000kVA – the Heavy Range industrial diesel generator range has been specially developed to meet industrial needs with high energy requirements. This range consists of containerized diesel generators designed to provide low or medium power.

AUTOMATIC DIESEL GENERATOR Grupel 65kW/81kVA

POWER: 65KVA/81KW

PHASES: THREE PHASE

FUEL: DIESEL

ENGINES
ALTERNATORS

AUTOMATIC DIESEL GENERATOR Grupel 65kW/81kVA
Produced by: Grupel
Made in: Portugal
Engine brand options: Baudouin, Grupel, FPT(Iveco), Perkins, Volvo
RPM: 1500 rpm
Cooling: Water (antifreeze coolant). Water heater to enable cold start.
Standby Power(ESP): 65kW (kilowatts)/81kVA (kilovoltampers)
Prime Power (PRP): 58kW (kilowatts)/73kVA (kilovoltampers)
Alternator brand options: Leroy Somer, Grupel
Number of phases: 3 (3-phases)
Output voltage: 400V
Frequency: 50 Hz
Start procedure: Automatic start. Remote start.
Control panel: Control panel with display. Option for distant management and monitoring enabled throgh ethernet protocol.
Fuel consumption @ 50% load: 9.1 liters per hour
Fuel consumption @ 75% load: 13.5 liters per hour
Fuel tank volume: 200 liters
Fuel tank options: Extended tank. Double-wall tank.
Continous work autonomy @ 75% load: 15 hours
Water & dust protection: IP23
Noise level @ 7 meters: 72 dB(A) (CE certified)
LхWхH (mm): 2330x1015x1580
Weight: 1478 kg.
KW: 65 kW
kVA: 81 kVA

  • DIESEL GENERATOR RENT OPTION

  • DIESEL GENERATOR  OPERATING LEASING OPTION

We, Heavy Industries Engineering team, provide full support on our machines during warranty period – it is our primary duty and we do it unconditionally and impeccably. That is why each of our projects ends not with the assembly and commissioning of our equipment, but two years later – with the expiration of the warranty period. Following this philosophy, we receive the highest rating by our clients for proven professionalism. Reasonable use of machinery extends far beyond warranty period and we know that the better they are maintained the longer they will serve you. Post-warranty maintenance is a reasonable and wise option to invest in the future of your devices. We offer wide-range services within maintenance field – long-term maintenance support, one-off checks, tests and change of consumables. Call us for more details.

DID YOU KNOW?

The small generators

Portable generators (up to 15kW) most often use gasoline as fuel. The more powerful – mandatory diesel fuel.

Three-phase electricity

If you have access to three-phase power grid, but your consumers are single-phase, a good option is to use a three-phase diesel generator plus a switchboard to allocate power over the phases.

Generator engine

The “heart” of the generator is the engine. Ordinary care for the engine should be taken – similar procedure as per cars’ engines. We recommend regular change of consumables (filters, oil, etc.) every 250 hours of operation or 2 years.

Autonomy of the generator

Automatic diesel generators are completely autonomous. They start automatically when the main grid is off, and when it is restored, they go into “stand by” mode. However, they need a little attention – checking the fuel level, starting battery, plus regular maintenance (by certified engineer).

Loss of main grid

When the main power is off, the generator starts up, but the power is restored only after 30-40 seconds? This is normal because the generator needs time to normalize its operation in order to be able to produce quality current.

Winter endeavor

How do generators start in winter? Modern machines have water heaters that keep the coolant warm during the cold months and thus the engine ready to start.

Power quality

My generator turns, but yet there is power from main grid… what’s the problem? Good generators constantly monitor the quality of the current – its voltage. When the voltage goes down or up significantly (+/- 10%), the generator switches on automatically and replaces the mains supply, and keeps on monitoring it until the voltage returns to normal limits. Thus, the generator protects electrical consumers from damage. This +/-10% tolerance can be increased through software programming, but we do not recommend doing so unless you plan to replace your appliances.

Noise

Generators emit noise when working. Low frequency, unobtrusive, usually not disturbing even sleeping people. EU-made generators meet all noise standards for such equipment.

Suitable place for the generator

When choosing a place to install the generator, some technical requirements should be taken into account, but it is also important to ensure the comfort of the users: choose a place away from the main activities in the property, away from the sleeping rooms in house, in the opposite direction of the prevailing winds.

Security measure

Soundproof generators installed outdoors are not dangerous for children and pets. However, we advise you to limit access to them as much as possible (Тhuja plants are an excellent solution).

In-house installation

Generators can also be installed indoor, in technical premises. In such a case, some additional installations should be made – for air inflow and exhaust gases, as well as requirements for safety of use and against fire.

Exhaust smoke

 

When starting the generator, a cloud of black smoke comes out of the exhaust, which immediately decreases to almost invisible values. This is normal and related to the infrequent use of the device.

Generator power

 

When you define the power of the generator, the electrical consumers to be reserved should be about 75% of generator’s prime power. This way you save some reserve at startup, as well as the ability to install additional equipment. On the other end, if the load is below 40% of the generator prime power, the machine is not working well and technical problems may occur. Think carefully, and best of all – give us a call – we’re professionals in reserved power engineering and can calculate precisely, plus to provide expertise.

When mains grid is restored

 

The time between the loss of mains power and its restart by the generator is about 40 seconds. This is a normal and technically necessary time. If you need certain consumers to not stop working even for a second – we will offer you a UPS device for that equipment.

Calculation of the consumed power

 

The mathematical sum of the consumption, taken from the plates of your appliances does not always give the total power required. If you have electric pumps or other appliances with electric motors, the starting current is higher than the rated current. Sometimes – significantly. You need to assess it and ensure the power of the generator takes into account this fact.